Full-bore (flowing full) capacity of a circular pipe running under gravity.
| Pipe diameter (D) |
Internal diameter
|
|---|---|
| Manning's n |
Pick a material or choose Custom to type a value
|
| Slope (S) |
%
Longitudinal grade of the pipe
|
| Full-bore velocity (V) | — |
|---|---|
| Full-bore flow (Q) | — |
| Flow area (A) | — |
| Hydraulic radius (R) | — |
Manning's equation is the workhorse of gravity-flow drainage design. Whenever you need to know how much water a stormwater or sewer pipe can carry under gravity — or whether a proposed pipe size and grade will pass the design flow — you are using Manning's equation, directly or through software. This calculator gives the full-bore capacity of a circular pipe: the velocity and flow when the pipe is running exactly full under gravity. It is the fast check drafters and designers reach for when reviewing a drainage layout: "is a 375 mm concrete pipe at 1 in 200 enough for this catchment?"
In SI (metric) form, Manning's equation is:
Q = (1/n) · A · R2/3 · S1/2, with velocity V = Q/A
where:
A key limitation to keep in mind: this is full-bore capacity only. It does not model part-full flow, and, counter-intuitively, a circular pipe's peak capacity (with a constant roughness) actually occurs at about 94% depth, not at 100%. Treat the full-bore figure as a capacity check, not a precise operating point.
| Material | Manning's n (design) |
|---|---|
| Concrete (precast RCP) | 0.013 |
| uPVC / smooth-wall plastic | 0.011 |
| HDPE, smooth wall | 0.011 |
| Corrugated HDPE / metal | 0.024 |
| Vitrified clay | 0.015 |
| Cast / ductile iron | 0.014 |
Note these are design values chosen towards the rougher end of published ranges, so that full-bore capacity is not over-estimated. Laboratory values for new, smooth pipes can be lower (finished concrete is often cited around 0.010–0.011), but Australian practice commonly designs to 0.013 for concrete to allow for jointing, ageing and site conditions.
Capacity is only half the story. Gravity drains also need enough velocity to stop solids settling out — the self-cleansing velocity. A commonly cited minimum is around 0.6–0.7 m/s (the traditional 2 ft/s ≈ 0.61 m/s), which is why standards set minimum pipe grades. Getting a pipe that "has capacity" but runs too slowly at low flows is a classic design miss. Confirm the minimum velocity and minimum grade requirements in the Queensland Urban Drainage Manual (QUDM) and the relevant council/water authority standards for your job.
Queensland Urban Drainage Manual (QUDM) for stormwater and pipe hydraulics; Manning's formula per standard hydraulics texts (e.g. Chow, Open-Channel Hydraulics, 1959); roughness coefficients cross-referenced to FHWA HDS-5. Local water authority and council design standards govern minimum grades, minimum velocities and acceptable n values on any real project — this calculator is a first-pass capacity check only.